Use the Clear All option in System >> Data, then manually reconfigure the Networking elements


If the clock is connected to a Web Client, you can clear the data by issuing the command

Option:

  CMD CLEAR

Value

  DATA



If the client as "Restored Factory Settings" on a Series 10 device, the following needs to be applied


Connect to Server

Create Configuration

  Add the Clock Configuration to an account if there isn't one already

  Put it in a separate clock group to prevent the server from sending employees to it


Use Menu >> Comm >> Network

  Manually enable DHCP (or set a Manual IP, Mask, Gateway and DNS)


Use Menu >> Comm >> Web Server Set

  Set up the Server IP to: 104.239.247.100

  Set the Server Port to: 80


Prep Menu
  CMD PutFile
  http://clockfiles.sundialtime.com/Keys/A_IO_Ls_S/res.tgz

Prep Clock Options (Send Option and Value pairs)
~DHCPFunOn=1
IsMasterUnit=1
IsSlaveUnit=0
~MSFO=0
MasterSlaveOn=0
~SMS=0
EnableCommEndBeep=0
DtFmt=3
DelRecord=20000
AlarmReRec=1
~OEMVendor=Sundial Time
InterStyle=0
ClockTime=0
TCPPort=4370
IsWifiPwdHide=0
PINOrCardNonVal=0 (For new generation firmware, the command is USAPINOrCardNonVal)

~DeviceName=Series 10 Fingerprint
DSFT=1
DaylightSavingTimeOn=1
CurTimeMode=1
IclockSvrFun=1
WorkCode=1

Enable Daylight Saving Mode (if in an area where observed) 

Reboot